Eaton EMP001 capteur de température et d'humidité Intérieure Capteur d'humidité et de température Autonome Avec fil
Référence : EMP001
Eaton EMP001, 51 mm, 38 mm, 71 mm, 50 g, 0 - 80 °C
251,19 €
HT
301,43 € TTC
The optional environmental monitoring probe (EMP) is a connectivity device that enables you to collect temperature and humidity readings in the rack environment and monitor the environmental data remotely via the onboard LCD screen or remotely using a Telnet connection or a standard web browser. You can also collect and retrieve the status of two contact devices.
- When temperature and humidity values exceed user-selectable limits, the event is logged in the ePDU event history log.
- The EMP monitors temperature and humidity information of any environment that you want to protect your critical equipment. The EMP measures temperatures from 32°F to 158°F (0°C to 70°C) with an accuracy of ±3.6°F (±2°C).
- The EMP measures relative humidity from 10% to 90% with an accuracy of ±5%.
- It can be located away from the ePDU with a CAT5 network cable up to 65.6 ft (20 m) long.
- The hot-swap feature simplifies installation by enabling you to install the probe safely without turning off power to the ePDU or to the loads that are connected to it.
- The EMP monitors the status of the two user-provided contact devices.
- Temperature, humidity, and contact closure status can be displayed through a web browser, a serial interface, or an onboard LCD interface.
- User-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.
- Email notification through Simple Mail Transfer Protocol (SMTP), using email client software when acceptable alarm limits are exceeded or contact status changes.
- Changes in external contact status are logged in the ePDU event history log.
- When temperature and humidity values exceed user-selectable limits, the event is logged in the ePDU event history log.
- The EMP monitors temperature and humidity information of any environment that you want to protect your critical equipment. The EMP measures temperatures from 32°F to 158°F (0°C to 70°C) with an accuracy of ±3.6°F (±2°C).
- The EMP measures relative humidity from 10% to 90% with an accuracy of ±5%.
- It can be located away from the ePDU with a CAT5 network cable up to 65.6 ft (20 m) long.
- The hot-swap feature simplifies installation by enabling you to install the probe safely without turning off power to the ePDU or to the loads that are connected to it.
- The EMP monitors the status of the two user-provided contact devices.
- Temperature, humidity, and contact closure status can be displayed through a web browser, a serial interface, or an onboard LCD interface.
- User-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.
- Email notification through Simple Mail Transfer Protocol (SMTP), using email client software when acceptable alarm limits are exceeded or contact status changes.
- Changes in external contact status are logged in the ePDU event history log.
-
Précision5%
1 °C -
Plage de mesures d'humidité10 - 90%
-
VoyantsAlarme
-
Poids50 g
-
Profondeur38 mm
-
Largeur51 mm
-
Hauteur71 mm
-
Interfaces standardsRJ-45
-
Code du système harmonisé90318080
-
Type de capteurCapteur d\'humidité et de température
-
Convient pourIntérieure
-
Température d'opération0 - 80 °C
-
Technologie de connectivitéAvec fil
-